ISO 80601-2-79:2024

مواصفة قياسية دولية   الإصدار الحالي · اعتمدت بتاريخ ٢٨ أغسطس ٢٠٢٤

Medical electrical equipment — Part 2-79: Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory impairment

ملفات الوثيقة ISO 80601-2-79:2024

الإنجليزية 107 صفحات
الإصدار الحالي
243.54 USD

مجال الوثيقة ISO 80601-2-79:2024

NOTE 1       There is guidance or rationale for this subclause contained in Clause AA.2.

This document applies to the basic safety and essential performance of ventilatory support equipment, as defined in 201.3.302, for ventilatory impairment, as defined in 201.3.300, hereafter also referred to as ME equipment, in combination with its accessories:

    intended for use in the home healthcare environment;

NOTE 2       In the home healthcare environment, the supply mains driving the ventilatory support equipment is often not reliable.

NOTE 3       Such ventilatory support equipment can also be used in professional health care facilities.

    intended for use by a lay operator;

    intended for use with patients who have ventilatory impairment, the most fragile of these patients, would not likely experience injury with the loss of this artificial ventilation; and

    not intended for patients who are dependent on artificial ventilation for their immediate life support.

EXAMPLE 1        Patients with mild to moderate chronic obstructive pulmonary disease (COPD).

Ventilatory support equipment is not considered to use a physiologic closed-loop control system unless it uses a physiological patient variable to adjust the artificial ventilation therapy settings.

This document is also applicable to those accessories intended by their manufacturer to be connected to the breathing system of ventilatory support equipment for ventilatory impairment, where the characteristics of those accessories can affect the basic safety or essential performance of the ventilatory support equipment for ventilatory impairment.

EXAMPLE 2        Breathing sets, connectors, water traps, expiratory valve, humidifier, breathing system filter, external electrical power source, distributed alarm system.

If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant.

Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in IEC 606011:2005+AMD1:2012+AMD2:2020, 7.2.13 and 8.4.1.

NOTE 4       Additional information can be found in IEC 606011:2005+AMD1:2012+AMD2:2020, 4.2.

NOTE 5       See ISO/TR 21954 for guidance on the selection of the appropriate ventilator for a given patient. 

This document does not specify the requirements for:

    ventilators or accessories for ventilator-dependent patients intended for critical care applications, which are given in ISO 806012‑12;

    ventilators or accessories intended for anaesthetic applications, which are given in ISO 806012‑13;

    ventilators or accessories intended for the emergency medical services environment, which are given in ISO 806012‑84;

    ventilators or accessories intended for ventilator-dependent patients in the home healthcare environment, which are given in ISO 806012‑72;

    ventilatory support equipment or accessories intended for ventilatory insufficiency, which are given in ISO 806012‑80;

    sleep apnoea therapy ME equipment, which are given in ISO 806012‑70;

    high-frequency jet ventilators (HFJVs), which are given in ISO 80601‑2‑87;

    high-frequency oscillatory ventilators (HFOVs);

    respiratory high flow equipment, which are given in ISO 80601‑2‑90;

NOTE 6     Ventilatory support equipment can incorporate high-flow therapy operational mode, but such a mode is only for spontaneously breathing patients.

    user-powered resuscitators, which are given in ISO 10651-4;

    gas-powered emergency resuscitators, which are given in ISO 10651-5;

    oxygen therapy constant flow ME equipment; and

    cuirass or “iron-lung” ventilation equipment.

الأكثر مبيعاً

GSO 150-2:2013
 
مواصفة قياسية خليجية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
YSMO GSO 150-2:2020
GSO 150-2:2013 
لائحة فنية يمنية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
GSO 2055-1:2015
 
لائحة فنية خليجية
الأغذية الحلال – الجزء الأول : الاشتراطات العامة للأغذية الحلال
YSMO GSO 150-1:2020
GSO 150-1:2013 
لائحة فنية يمنية
فترات صلاحية المنتجات الغذائية - الجزء الأول : فترات الصلاحية الإلزامية

اعتمدت مؤخراً

ISO 7944:2024
 
مواصفة قياسية دولية
Optics and photonics — Reference wavelengths
ISO 21498-2:2024
 
مواصفة قياسية دولية
Electrically propelled road vehicles — Electrical specifications and tests for voltage class B systems and components — Part 2: Electrical tests for components
ISO 23551-1:2024
 
مواصفة قياسية دولية
Safety and control devices for gas burners and gas-burning appliances — Particular requirements — Part 1: Automatic and semi-automatic shut-off valves
ISO 13695:2024
 
مواصفة قياسية دولية
Optics and photonics — Lasers and laser-related equipment — Test methods for the spectral characteristics of lasers