GSO IEC 60601-2-68:2017
IEC 60601-2-68:2014
Gulf Standard
Current Edition
·
Approved on
03 October 2017
Electrical medical equipment - Part 2-68: Particular requirements for the basic safety and essential performance of X-ray-based image-guided radiotherapy equipment for use with electron accelerators, light ion beam therapy equipment and radionuclide beam
GSO IEC 60601-2-68:2017 Files
No files are available for this standard right now!
GSO IEC 60601-2-68:2017 Scope
Replacement:
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of X-ray based IMAGE-GUIDED RADIOTHERAPY equipment for use with EXTERNAL BEAM EQUIPMENT (EBE).
This particular standard covers safety aspects of kilovoltage (kV) and megavoltage (MV) X-ray imaging devices in a known geometrical relationship with EBE for the purpose of IGRT. It covers aspects of communication and relationships between the EXTERNAL BEAM EQUIPMENT and X-ray imaging devices, attached or not directly attached to, but in the same RADIATION shielded area as, and dedicated for use only with the EXTERNAL BEAM EQUIPMENT.
This particular standard deals with equipment for REAL-TIME X-IGRT, ONLINE X-IGRT and OFFLINE X-IGRT. It covers procedures to reduce the risk of over-reliance on the X-IGRT EXTERNAL BEAM SYSTEM (X-IGRT EBS). For example the manufacturer will provide an interactive interface for user interaction with the correction suggested by the system.
If a clause or subclause is specifically intended to be applicable to X-IGRT EBE SYSTEMS the content of that clause or subclause will say so. If that is not the case, the clause or subclause applies only to X-IGRT EQUIPMENT.
This particular standard, with the inclusion of TYPE TESTS and SITE TESTS, applies respectively to the MANUFACTURER and some installation aspects of X-IGRT EBE SYSTEMS intended to be
• for NORMAL USE, operated under the authority of appropriately licensed or QUALIFIED PERSONS by OPERATORS having the required skills for a particular medical application, for particular specified clinical purposes, e.g. STATIONARY RADIOTHERAPY or MOVING BEAM RADIOTHERAPY
• maintained in accordance with the recommendations given in the INSTRUCTIONS FOR USE,
• subject to regular quality assurance performance and calibration checks by a QUALIFIED PERSON.
NOTE In this particular standard, all references to installation refer to installation in the RESPONSIBLE ORGANIZATION’S premises
Best Sellers From Electrical Sector
YSMO GSO 2530:2023
GSO 2530:2016
Yemeni Technical Regulation
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
Recently Published from Electrical Sector
GSO 2770:2024
Gulf Standard
WATER HEATERS - ENERGY PERFORMANCE REQUIREMENTS
GSO IEC 61508-7:2024
IEC 61508-7:2010
Gulf Standard
Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures (see Functional Safety and IEC 61508)
GSO IEC 62148-17:2024
IEC 62148-17:2023
Gulf Standard
Fibre optic active components and devices - Package and interface standards - Part 17: Transmitter and receiver components with dual coaxial RF connectors
GSO IEC 63027:2024
IEC 63027:2023
Gulf Standard
Photovoltaic power systems - DC arc detection and interruption