GSO IEC 60601-2-66:2017

IEC 60601-2-66:2015
Gulf Standard   Current Edition · Approved on 03 October 2017

Medical electrical equipment - Part 2-66: Particular requirements for the basic safety and essential performance of hearing instruments and hearing instrument systems

GSO IEC 60601-2-66:2017 Files

GSO IEC 60601-2-66:2017 Scope

Replacement: This International Standard applies to the BASIC SAFETY of HEARING INSTRUMENTS and HEARING INSTRUMENT SYSTEMS, hereafter also referred to as ME EQUIPMENT or ME SYSTEM. If a clause or subclause is specifically intended to be applicable to HEARING INSTRUMENTS only, or to HEARING INSTRUMENT SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to HEARING INSTRUMENTS and to HEARING INSTRUMENT SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of HEARING INSTRUMENTS or HEARING INSTRUMENT SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 201.7.9.2 and 201.9.6. NOTE See also 201.4.2. (RISK MANAGEMENT). ACCESSORIES to HEARING INSTRUMENTS in the HOME HEALTHCARE ENVIRONMENT (e.g. remote control units, audio streamers, battery chargers, power supplies) are covered by the most applicable standard, IEC 60065, IEC 60950-1 or other applicable IEC safety standards. Alternatively the general standard may be applied. HEARING INSTRUMENTS do not have a MAINS PART intended for connection to a.c. SUPPLY MAINS. The connection to the SUPPLY MAINS of a HEARING INSTRUMENT system is covered by power supply, charger or other types of ACCESSORIES. ACCESSORIES connected to a HEARING INSTRUMENT may form a HEARING INSTRUMENT SYSTEM. Only the HEARING INSTRUMENT and its detachable parts are subject to all applicable clauses of this particular standard. The remaining components of the HEARING INSTRUMENT SYSTEM are subject to requirements of this particular standard that result from their connection to the HEARING INSTRUMENT SYSTEM. Programming interfaces or ACCESSORIES in a clinical application are covered by the general standard. NOTE Detachable parts of HEARING INSTRUMENTS even if supplied separately (e.g. ear hooks, domes, wax guards etc.), are not regarded as ACCESSORIES. This standard does not apply to: – cochlear implants or other implanted HEARING INSTRUMENTS; – bone conduction HEARING INSTRUMENTS; – educational HEARING INSTRUMENTS (i.e. group HEARING INSTRUMENTS, auditory trainers etc.); – the application of a HEARING INSTRUMENT for the measurement of hearing levels. IEC 60645-1 applies; – audio-frequency induction-loop systems or their component parts, as described in IEC 60118-4 and IEC 62489-1; – assisted HEARING INSTRUMENT SYSTEMS using infra-red or radio; – the sound generating function of a tinnitus masker.

Best Sellers From Electrical Sector

YSMO GSO 2530:2023
GSO 2530:2016 
Yemeni Technical Regulation
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines

Recently Published from Electrical Sector

GSO 2770:2024
 
Gulf Standard
WATER HEATERS - ENERGY PERFORMANCE REQUIREMENTS
GSO IEC 63027:2024
IEC 63027:2023 
Gulf Standard
Photovoltaic power systems - DC arc detection and interruption
GSO IEC 60885-3:2024
IEC 60885-3:2015 
Gulf Standard
Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables
GSO IEC TS 62257-9-2:2024
IEC TS 62257-9-2:2016 
Gulf Standard
Recommendations for renewable energy and hybrid systems for rural electrification - Part 9-2: Integrated systems - Microgrids