ISO 19581:2025

International Standard   Current Edition · Approved on 24 September 2025

Measurement of radioactivity — Gamma emitting radionuclides — Rapid screening method using scintillation detector gamma-ray spectrometry

ISO 19581:2025 Files

English 22 Pages
Current Edition
165.98 USD

ISO 19581:2025 Scope

This document specifies a screening test method to quantify rapidly the activity concentration of gamma-emitting radionuclides, such as 131I, 132Te, 134Cs and 137Cs, in solid or liquid test samples using gamma-ray spectrometry with lower resolution scintillation detectors as compared with the HPGe detectors (see IEC 61563[7]).

This test method can be used for the measurement of any potentially contaminated environmental matrices (including soil), food and feed samples as well as industrial materials or products that have been properly conditioned[8]. Sample preparation techniques used in the screening method are not specified in this document, since special sample preparation techniques other than simple machining (cutting, grinding, etc.) should not be required. Although the sampling procedure is of utmost importance in the case of the measurement of radioactivity in samples, it is out of scope of this document; other International Standards for sampling procedures that can be used in combination with this document are available (see References [9] [10] [11] [12] [13] [14]).

The test method applies to the measurement of gamma-emitting radionuclides such as 131I, 134Cs and 137Cs. Using sample sizes of 0,5 l to 1,0 l in a Marinelli beaker and a counting time of 5 min to 20 min, decision threshold of 10 Bq·kg−1 can be achievable using a commercially available scintillation spectrometer [e.g. thallium activated sodium iodide (NaI(Tl)) spectrometer 2” ϕ × 2” (50,8 mm Ø x 50,8 mm) detector size, 7 % resolution (FWHM) at 662 keV, 30 mm lead shield thickness].

This test method also can be performed in a “makeshift” laboratory or even outside a testing laboratory on samples directly measured in the field where they were collected.

During a nuclear or radiological emergency, this test method enables a rapid measurement of the activity concentration of potentially contaminated samples to check against operational intervention levels (OILs) set up by decision makers that would trigger a predetermined emergency response to reduce existing radiation risks[2].

Due to the uncertainty associated with the results obtained with this test method, test samples requiring more accurate test results can be measured using high purity germanium (HPGe) detectors gamma-ray spectrometry in a testing laboratory, following appropriate preparation of the test samples[15][16].

This document does not contain criteria to establish the activity concentration of OILs.

Best Sellers

GSO 150-2:2013
 
Gulf Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
YSMO GSO 150-2:2020
GSO 150-2:2013 
Yemeni Technical Regulation
Expiration dates for food products - Part 2 : Voluntary expiration dates
YSMO GSO 2055-1:2020
GSO 2055-1:2015 
Yemeni Standard
HALAL FOOD - Part 1 : General Requirements
GSO 2055-1:2015
 
Gulf Technical Regulation
HALAL FOOD - Part 1 : General Requirements

Recently Published

ISO 24690:2025
 
International Standard
Glass reinforced thermosetting plastic (GRP) pipes — Test method for the determination of long-term pressure endurance strength
ISO 15614-11:2025
 
International Standard
Specification and qualification of welding procedures for metallic materials — Welding procedure test — Part 11: Electron and laser beam welding
IEC/TS 81001-2-2:2025
 
International Standard
Health software and health IT systems safety, effectiveness and security — Part 2-2: Guidance for the implementation, disclosure and communication of security needs, risks and controls
ISO 37190:2025
 
International Standard
Guidance for practical implementation of ISO 37155 series for supervising at each life cycle phase of smart community infrastructures