ISO 19581:2025

مواصفة قياسية دولية   الإصدار الحالي · اعتمدت بتاريخ ٢٤ سبتمبر ٢٠٢٥

Measurement of radioactivity — Gamma emitting radionuclides — Rapid screening method using scintillation detector gamma-ray spectrometry

ملفات الوثيقة ISO 19581:2025

الإنجليزية 22 صفحات
الإصدار الحالي
USD 171.1

مجال الوثيقة ISO 19581:2025

This document specifies a screening test method to quantify rapidly the activity concentration of gamma-emitting radionuclides, such as 131I, 132Te, 134Cs and 137Cs, in solid or liquid test samples using gamma-ray spectrometry with lower resolution scintillation detectors as compared with the HPGe detectors (see IEC 61563[7]).

This test method can be used for the measurement of any potentially contaminated environmental matrices (including soil), food and feed samples as well as industrial materials or products that have been properly conditioned[8]. Sample preparation techniques used in the screening method are not specified in this document, since special sample preparation techniques other than simple machining (cutting, grinding, etc.) should not be required. Although the sampling procedure is of utmost importance in the case of the measurement of radioactivity in samples, it is out of scope of this document; other International Standards for sampling procedures that can be used in combination with this document are available (see References [9] [10] [11] [12] [13] [14]).

The test method applies to the measurement of gamma-emitting radionuclides such as 131I, 134Cs and 137Cs. Using sample sizes of 0,5 l to 1,0 l in a Marinelli beaker and a counting time of 5 min to 20 min, decision threshold of 10 Bq·kg−1 can be achievable using a commercially available scintillation spectrometer [e.g. thallium activated sodium iodide (NaI(Tl)) spectrometer 2” ϕ × 2” (50,8 mm Ø x 50,8 mm) detector size, 7 % resolution (FWHM) at 662 keV, 30 mm lead shield thickness].

This test method also can be performed in a “makeshift” laboratory or even outside a testing laboratory on samples directly measured in the field where they were collected.

During a nuclear or radiological emergency, this test method enables a rapid measurement of the activity concentration of potentially contaminated samples to check against operational intervention levels (OILs) set up by decision makers that would trigger a predetermined emergency response to reduce existing radiation risks[2].

Due to the uncertainty associated with the results obtained with this test method, test samples requiring more accurate test results can be measured using high purity germanium (HPGe) detectors gamma-ray spectrometry in a testing laboratory, following appropriate preparation of the test samples[15][16].

This document does not contain criteria to establish the activity concentration of OILs.

الأكثر مبيعاً

YSMO GSO 150-2:2020
GSO 150-2:2013 
لائحة فنية يمنية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
GSO 150-2:2013
 
مواصفة قياسية خليجية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
GSO 9:2022
 
لائحة فنية خليجية
بطاقات المواد الغذائية المعبأة
YSMO GSO 2055-1:2020
GSO 2055-1:2015 
مواصفة قياسية يمنية
الأغذية الحلال – الجزء الأول : الاشتراطات العامة للأغذية الحلال

اعتمدت مؤخراً

ISO 15027-3:2026
 
مواصفة قياسية دولية
Immersion suits — Part 3: Test methods
ISO 15027-1:2026
 
مواصفة قياسية دولية
Immersion suits — Part 1: Safety and performance requirements for constant wear suits
ISO/IEC TS 23220-4:2026
 
مواصفة قياسية دولية
Cards and security devices for personal identification — Building blocks for identity management via mobile devices — Part 4: Protocols and services for operational phase
ISO/IEC TS 23220-2:2026
 
مواصفة قياسية دولية
Cards and security devices for personal identification — Building blocks for identity management via mobile devices — Part 2: Data objects and encoding rules for generic eID systems