ISO 80601-2-61:2026

مواصفة قياسية دولية   الإصدار الحالي · اعتمدت بتاريخ ١٠ أبريل ٢٠٢٦

Medical electrical equipment — Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment

ملفات الوثيقة ISO 80601-2-61:2026

الإنجليزية 150 صفحات
الإصدار الحالي
USD 289.29

مجال الوثيقة ISO 80601-2-61:2026

This document applies to the basic safety and essential performance of pulse oximeter equipment intended for use on humans, hereafter referred to as ME equipment. This includes any part necessary for normal use, including the pulse oximeter monitor, pulse oximeter probe, and probe cable extender.

These requirements apply to pulse oximeter equipment, including pulse oximeter monitors, pulse oximeter probes and probe cable extenders regardless of their origin (i.e. including remanufactured products).

The intended use of pulse oximeter equipment includes, but is not limited to, the estimation of arterial oxygen haemoglobin saturation and pulse rate of patients in professional healthcare institutions as well as patients in the home healthcare environment and the emergency medical services environment.

If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause says so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant.

Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in 201.11.1.2.2, IEC 60601-1:2005+AMD1:2012+AMD2:2020, 7.2.13 and 8.4.1.

NOTE 2        See also IEC 60601-1:2005+AMD1:2012+AMD2:2020, 4.2.

This document can also be applied to ME equipment and their accessories used for compensation or alleviation of disease, injury, or disability.

This document is not applicable to pulse oximeter equipment intended for use in laboratory research applications nor to oximeters that require a blood sample from the patient.

This document is not applicable to pulse oximeter equipment intended solely for foetal use.

This document is not applicable to remote or slave (secondary) equipment that displays SpO2 values that are located outside of the patient environment.

NOTE 3        ME equipment that provides selection between diagnostic and monitoring functions is expected to meet the appropriate requirements of this document when configured for that function.

This document is applicable to pulse oximeter equipment intended for use under extreme or uncontrolled environmental conditions outside the hospital environment or physician’s office, such as in ambulances and air transport. Additional standards can apply to pulse oximeter equipment for those environments of use.

This document is a particular standard in the IEC 60601-1 and ISO and IEC 80601 series of standards.

الأكثر مبيعاً

YSMO GSO 150-2:2020
GSO 150-2:2013 
لائحة فنية يمنية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
GSO 150-2:2013
 
مواصفة قياسية خليجية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
GSO 9:2022
 
لائحة فنية خليجية
بطاقات المواد الغذائية المعبأة
YSMO GSO 2055-1:2020
GSO 2055-1:2015 
مواصفة قياسية يمنية
الأغذية الحلال – الجزء الأول : الاشتراطات العامة للأغذية الحلال

اعتمدت مؤخراً

IEC 81346-14:2026
 
مواصفة قياسية دولية
Industrial systems, installations and equipment and industrial products — Structuring principles and reference designations — Part 14: Manufacturing and processing systems
ISO 10583:2026
 
مواصفة قياسية دولية
Aerospace fluid systems — Test methods for fitting on tube assemblies
ISO 18379-1:2026
 
مواصفة قياسية دولية
Railway infrastructure — Ballastless track — Part 1: General requirements
ISO 8810:2026
 
مواصفة قياسية دولية
Plastics — Determination of residual peroxide — Gas chromatography method