ISO 15883-4:2018

International Standard   Current Edition · Approved on 12 November 2018

Washer-disinfectors — Part 4: Requirements and tests for washer-disinfectors employing chemical disinfection for thermolabile endoscopes

ISO 15883-4:2018 Files

English 81 Pages
Current Edition
USD 280.3

ISO 15883-4:2018 Scope

This document specifies the particular requirements, including performance criteria for washer-disinfectors (WD) that are intended to be used for cleaning and chemical disinfection of thermolabile endoscopes.

This document also specifies the performance requirements for the cleaning and disinfection of the washer-disinfector and its components and accessories which can be required to achieve the necessary performance criteria.

The methods, instrumentation and instructions required for type testing, works testing, validation (installation, operational and performance qualification on first installation), routine control and monitoring, and requalification of WD periodically and after essential repairs, are also specified.

NOTE 1 In addition, Annex A gives guidance on an appropriate division of responsibility for the range of activities covered by this document.

NOTE 2 WD complying with this document can also be used for cleaning and chemical disinfection of other thermolabile re-usable medical devices for which the device manufacturer has recommended and validated this method of disinfection.

WD complying with the requirements of this document are not intended for cleaning and disinfection of medical devices, including endoscopic accessories, which are heat stable and can be disinfected or sterilized by thermal methods (see ISO 15883-1:2006+Amd 1:2014, 4.1.5).

The specified performance requirements of this document do not ensure the inactivation or removal of the causative agent(s) (prion protein) of transmissible spongiform encephalopathies.

NOTE 3 If it is considered that prion protein might be present, particular care is needed in the choice of cleaning agents and disinfectants to ensure that the chemicals used do not react with the prion protein and/or other protein in a manner that can inhibit its removal or inactivation from the load or washer-disinfector.

NOTE 4 This document can be used by prospective purchasers and manufacturers as the basis of agreement on the specification of the WD, manufacturers of endoscopes, cleaning products, and disinfecting products.

Best Sellers

GSO 150-2:2013
 
Gulf Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
YSMO GSO 150-2:2020
GSO 150-2:2013 
Yemeni Technical Regulation
Expiration dates for food products - Part 2 : Voluntary expiration dates
GSO 9:2022
 
Gulf Technical Regulation
Labeling of prepackaged food stuffs
YSMO GSO 2055-1:2020
GSO 2055-1:2015 
Yemeni Standard
HALAL FOOD - Part 1 : General Requirements

Recently Published

ISO 14855-2:2026
 
International Standard
Determination of the ultimate aerobic biodegradability of plastic materials under controlled composting conditions — Method by analysis of evolved carbon dioxide — Part 2: Gravimetric measurement of carbon dioxide evolved in a laboratory-scale test
ISO/TR 5503:2026
 
International Standard
Preparation of steel substrates before application of paints and related products — Non-visible residues after surface preparation with single use abrasives — Relationship between conductivity (Bresle) measurements and surface soluble salt composition on panels blasted with single-use mineral abrasives
ISO 4683-3:2026
 
International Standard
Raw sheep skins — Part 3: Guidelines for grading on the basis of mass and size
ISO/IEC 25791-1:2026
 
International Standard
Information technology — OpenID Connect FAPI Security Profile 1.0 — Part 1: Baseline