GSO IEC 61083-2:2025
IEC 61083-2:2013
Gulf Standard
Current Edition
·
Approved on
14 October 2025
Instruments and software used for measurement in high-voltage and high-current tests - Part 2: Requirements for software for tests with impulse voltages and currents
GSO IEC 61083-2:2025 Files
No files for this standard are available in the store currently.
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
GSO IEC 61083-2:2025 Scope
IEC 61083-2:2013 applies to software used for evaluation of impulse parameters from recorded impulse voltages and currents. It provides test waveforms and reference values for the software required to meet the measuring uncertainties and procedures specified in IEC 60060-1, IEC 60060-2, IEC 60060-3 and IEC 62475. Hardware with built-in firmware that cannot accept external numerical input data is not covered by this standard. The object of this standard is to establish the tests which are necessary to show that the performance of the software complies with the requirements of the relevant IEC standards, define the terms specifically related to digital processing, specify reference values and the acceptance limits for the reference impulses, specify the requirements for the record of performance and define the methods to assess the contribution of software to the measurement uncertainty. This second edition cancels and replaces the first edition published in 1996 and constitutes a technical revision. The main changes with respect to the previous edition are:
- the test data generator software has been updated,
- the number of reference impulse waveforms included in the test data generator has been significantly increased,
- all reference values have been recalculated according to new definitions in IEC 60060-1 and IEC 62475 and
- methods for estimating the uncertainty of parameter evaluation have been introduced and are in line with the procedure introduced in IEC 60060-2. Keywords: High voltage, High current, Impulse voltage, Impulse current.
- the test data generator software has been updated,
- the number of reference impulse waveforms included in the test data generator has been significantly increased,
- all reference values have been recalculated according to new definitions in IEC 60060-1 and IEC 62475 and
- methods for estimating the uncertainty of parameter evaluation have been introduced and are in line with the procedure introduced in IEC 60060-2. Keywords: High voltage, High current, Impulse voltage, Impulse current.
Best Sellers From Electrical Sector
YSMO GSO 2530:2023
GSO 2530:2016
Yemeni Technical Regulation
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
Recently Published from Electrical Sector
GSO IEC 62841-4-1:2025
IEC 62841-4-1:2017
Gulf Standard
Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery - Safety - Part 4-1: Particular requirements for chain saws
GSO IEC 63203-402-3:2025
IEC 63203-402-3:2024
Gulf Standard
Wearable electronic devices and technologies - Part 402-3: Performance measurement of fitness wearables - Test methods for the determination of the accuracy of heart rate
GSO IEC 61010-2-033:2025
IEC 61010-2-033:2023
Gulf Standard
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage
GSO IEC 62933-5-3:2025
IEC 62933-5-3:2023
Gulf Standard
Electrical energy storage (EES) systems - Part 5-3: Safety requirements for grid-integrated EES systems – Performing unplanned modification of electrochemical based system