GSO IEC 61347-2-2:2025
IEC 61347-2-2:2024
Gulf Standard
Current Edition
·
Approved on
14 October 2025
Controlgear for electric light sources - Safety - Part 2-2: Particular requirements - Electronic step-down convertors for filament lamps
GSO IEC 61347-2-2:2025 Files
English
21 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
GSO IEC 61347-2-2:2025 Scope
IEC 61347-2-2:2024 specifies safety requirements for electronic step-down convertors for use on DC supplies of up to 1 500 V or AC supplies of up to 1 000 V at 50 Hz or 60 Hz, and with a rated output voltage ≤ 50 V (RMS) at a frequency deviating from the supply frequency, or 120 V ripple free DC between conductors and between any conductor and earth, associated with tungsten-halogen lamps as specified in IEC 60357, and other filament lamps.
This third edition cancels and replaces the second edition published in 2011. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment with respect to the fourth edition of IEC 61347-1;
- introduction of dated references to the fourth edition of IEC 61347-1 as appropriate;
- deletion of the clauses and subclauses which are either no longer relevant or now covered in IEC 61347-1;
b) scope extension to 1 500 V for direct current;
c) scope clarification;
d) deletion of unused definitions;
e) revision of information and marking requirements;
f) revision of compliance conditions for the measurement of the output voltage during fault condition testing and during thermal testing.
This third edition cancels and replaces the second edition published in 2011. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment with respect to the fourth edition of IEC 61347-1;
- introduction of dated references to the fourth edition of IEC 61347-1 as appropriate;
- deletion of the clauses and subclauses which are either no longer relevant or now covered in IEC 61347-1;
b) scope extension to 1 500 V for direct current;
c) scope clarification;
d) deletion of unused definitions;
e) revision of information and marking requirements;
f) revision of compliance conditions for the measurement of the output voltage during fault condition testing and during thermal testing.
Best Sellers From Electrical Sector
YSMO GSO 2530:2023
GSO 2530:2016
Yemeni Technical Regulation
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
Recently Published from Electrical Sector
GSO IEC 62973-3:2025
IEC 62973-3:2024
Gulf Standard
Railway applications - Rolling stock - Batteries for auxiliary power supply systems - Part 3: Lead acid batteries
GSO IEC 60352-2:2025
IEC 60352-2:2024
Gulf Standard
Solderless connections - Part 2: Crimped connections - General requirements, test methods and practical guidance
GSO IEC 60034-2-3:2025
IEC 60034-2-3:2024
Gulf Standard
Rotating electrical machines - Part 2-3: Specific test methods for determining losses and efficiency of converter-fed AC motors
GSO IEC 60404-12:2025
IEC 60404-12:2023
Gulf Standard
Magnetic materials - Part 12: Methods of test for the assessment of the thermal endurance of surface insulation coatings on electrical steel strip and sheet