GSO IEC 60079-11:2024 Scope
IEC 60079-11:2023 (EN) specifies the construction and testing of intrinsically safe apparatus intended for use in explosive atmospheres, and for associated apparatus which is intended for connection to intrinsically safe circuits which enter such atmospheres.
This Type of Protection is applicable to electrical equipment in which the electrical circuits themselves are incapable of causing ignition of a surrounding explosive atmosphere. This includes electrical equipment which contains circuits that are intrinsically safe only under certain conditions, for example under battery supply with mains supply removed.
This document is also applicable to electrical equipment or parts of electrical equipment located outside the explosive atmosphere or protected by another Type of Protection listed in IEC 60079 0, where the intrinsic safety of the electrical circuits in the explosive atmosphere may depend upon the design and construction of such electrical equipment or parts of such electrical equipment. The electrical circuits exposed to the explosive atmosphere are assessed for use in such atmospheres by applying this document.
This document applies to sensors connected to intrinsically safe circuits but does not apply to the protection of catalytic elements for Group IIC or Group IIB + H2.
This document does not apply to Ex Equipment cable glands.
The requirements for intrinsically safe systems are provided in IEC 60079-25.
This document supplements and modifies the general requirements of IEC 60079-0, except as indicated in Table 1. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence.
Unless otherwise stated, the requirements in this document are applicable to both intrinsically safe apparatus and associated apparatus, and the generic term "apparatus" is used throughout the standard.
As this document applies only to electrical equipment, the term "equipment" used in the standard always means "electrical equipment".
This document applies to apparatus for use under the atmospheric conditions of IEC 60079 0 with additional requirements for use at extended atmospheric pressures in the range from 60 kPa (0,6 bar), up to 110 kPa (1,1 bar).
This seventh edition cancels and replaces the sixth edition published in 2011. This edition constitutes a technical revision.
The identification and significance of the changes between IEC 60079-11, Edition 7 (2022) and IEC 60079-11, Edition 6 (2011 + Corrigendum 1 (2012)) can be found in the table of changes in the foreword of the publication.
The contents of the corrigendum of June 2023 have been included in this copy.
This Type of Protection is applicable to electrical equipment in which the electrical circuits themselves are incapable of causing ignition of a surrounding explosive atmosphere. This includes electrical equipment which contains circuits that are intrinsically safe only under certain conditions, for example under battery supply with mains supply removed.
This document is also applicable to electrical equipment or parts of electrical equipment located outside the explosive atmosphere or protected by another Type of Protection listed in IEC 60079 0, where the intrinsic safety of the electrical circuits in the explosive atmosphere may depend upon the design and construction of such electrical equipment or parts of such electrical equipment. The electrical circuits exposed to the explosive atmosphere are assessed for use in such atmospheres by applying this document.
This document applies to sensors connected to intrinsically safe circuits but does not apply to the protection of catalytic elements for Group IIC or Group IIB + H2.
This document does not apply to Ex Equipment cable glands.
The requirements for intrinsically safe systems are provided in IEC 60079-25.
This document supplements and modifies the general requirements of IEC 60079-0, except as indicated in Table 1. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence.
Unless otherwise stated, the requirements in this document are applicable to both intrinsically safe apparatus and associated apparatus, and the generic term "apparatus" is used throughout the standard.
As this document applies only to electrical equipment, the term "equipment" used in the standard always means "electrical equipment".
This document applies to apparatus for use under the atmospheric conditions of IEC 60079 0 with additional requirements for use at extended atmospheric pressures in the range from 60 kPa (0,6 bar), up to 110 kPa (1,1 bar).
This seventh edition cancels and replaces the sixth edition published in 2011. This edition constitutes a technical revision.
The identification and significance of the changes between IEC 60079-11, Edition 7 (2022) and IEC 60079-11, Edition 6 (2011 + Corrigendum 1 (2012)) can be found in the table of changes in the foreword of the publication.
The contents of the corrigendum of June 2023 have been included in this copy.
Best Sellers From Electrical Sector
YSMO GSO 2530:2023
GSO 2530:2016
Yemeni Technical Regulation
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
Recently Published from Electrical Sector
GSO 2770:2024
Gulf Standard
WATER HEATERS - ENERGY PERFORMANCE REQUIREMENTS
GSO IEC 61508-7:2024
IEC 61508-7:2010
Gulf Standard
Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures (see Functional Safety and IEC 61508)
GSO IEC 62148-17:2024
IEC 62148-17:2023
Gulf Standard
Fibre optic active components and devices - Package and interface standards - Part 17: Transmitter and receiver components with dual coaxial RF connectors
GSO IEC 63027:2024
IEC 63027:2023
Gulf Standard
Photovoltaic power systems - DC arc detection and interruption