GSO ISO 52016-3:2024

ISO 52016-3:2023
Gulf Standard   Current Edition · Approved on 14 October 2024

Energy performance of buildings — Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads — Part 3: Calculation procedures regarding adaptive building envelope elements

GSO ISO 52016-3:2024 Files

GSO ISO 52016-3:2024 Scope

This document specifies procedures for the calculation of the energy needs for heating and cooling, internal temperatures and sensible and latent heat loads of a building according to the hourly calculation methodology in ISO 52016-1. Additions or modifications of the calculations are provided in this document if the building envelope contains one or more adaptive building envelope elements (building envelope elements with adaptive components that are either environmentally or actively controlled as a function of specific conditions). The adaptive building envelope element replaces the transparent building element in the calculation according to ISO 52016-1.

The three types of adaptive building envelope elements covered in this document are:

—     building envelope elements with dynamic solar shading;

—     building envelope elements with chromogenic glazing;

—     building envelope elements with an actively ventilated cavity.

Environmentally activated control is described for building envelope elements with chromogenic glazing, but can also occur for other types of adaptive building envelope elements. In that case the same approach applies as for environmentally activated chromogenic glazing.

This document is applicable to the assessment of the energy performance of buildings (EPB) (energy performance labels and certificates), including comparison between buildings and checking conformity with minimum energy performance criteria.

It is also applicable to assess the contribution of the adaptive building envelope element to the smart readiness of a building.

In addition, this document provides indicators for the impact of the adaptive building envelope element on the performance of the building compared to a reference building envelope element. It is applicable to buildings at the design stage, to new buildings after construction and to existing buildings in the use phase.

This document is not applicable to geometrically complex adaptive building envelope elements that can only be modelled as multiple coupled thermal zones.

NOTE            The background to the selection of adaptive building envelope elements is given in ISO/TR 52016-4.

Best Sellers From Construction and Building Sector

GSO 1427:2008
 
Gulf Standard
Ceramic Sanitary Appliances - Western Water Closets
GSO 1431:2002
 
Gulf Technical Regulation
Sanitary appliances - pressurized flushing devices
GSO 2489:2015
 
Gulf Standard
Specifications of Recycled Aggregates from Construction Waste to be used in construction Works
GSO 2084:2010
 
Gulf Standard
Design and application of speed control humps

Recently Published from Construction and Building Sector

GSO EN 13888-1:2026
EN 13888-1:2022 
Gulf Standard
Grouts for ceramic tiles - Part 1: Requirements, classification, designation, marking and labelling
GSO ISO 16535:2026
ISO 16535:2019 
Gulf Standard
Thermal insulating products for building applications — Determination of long-term water absorption by immersion
GSO ISO 679:2026
ISO 679:2009 
Gulf Standard
Cement — Test methods — Determination of strength
GSO ISO 50002-2:2026
ISO 50002-2:2025 
Gulf Standard
Energy audits — Part 2: Guidance for conducting an energy audit using ISO 50002-1 in buildings