GSO ASTM E2397/E2397M:2024
ASTM E2397/E2397M:19
Gulf Standard
Current Edition
·
Approved on
25 April 2024
Standard Practice for Determination of Dead Loads and Live Loads Associated with Vegetative (Green) Roof Systems
GSO ASTM E2397/E2397M:2024 Files
No files are available for this standard right now!
GSO ASTM E2397/E2397M:2024 Scope
1.1 This practice covers a standardized procedure for predicting the system weight of a vegetative (green) roof system.
1.2 The practice addresses the loads associated with vegetative (green) roof systems. Components that are typically
encountered in vegetative (green) roof systems include:
membranes, non-absorptive plastic sheet components, metallic
layers, fabrics, Geo composite drain layers, synthetic reinforcing layers, cover/recover boards, insulation materials, growth
media, granular drainage media, and plant materials.
1.3 This practice also addresses the weight of the vegetative
(green) roof system under two conditions: (1) weight under
drained conditions after new water additions by rainfall or
irrigation have ceased (this includes the weight of retained
water and captured water), and (2) weight when rainfall or
irrigation is actively occurring and the drain layer is completely
filled with water. The first condition is considered the dead load
of the vegetative (green) roof system. The difference in weight
between the first and second conditions, approximated by the
weight of transient water in the drain layer, is considered a live
load.
1.4 This practice does not address point or line loads
associated with architectural elements that are not essential
components of a particular vegetative (green) roof system.
These architectural elements may include pavement, walls, and
masonry, and so forth.
1.5 This practice does not address live loads associated with
construction activities.
1.6 This practice does not address loads associated with
snow or wind.
1.7 The values stated in either SI units or inch-pound units
are to be regarded separately as standard. The values stated in
each system may not be exact equivalents; therefore, each
system shall be used independently of the other. Combining
values from the two systems may result in non-conformance
with the standard.
1.8 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and to
determine the applicability of regulatory limitations prior to
use.
1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee.
Best Sellers From Construction and Building Sector
GSO 1431:2002
Gulf Technical Regulation
Sanitary appliances - pressurized flushing devices
GSO 1427:2008
Gulf Standard
Ceramic Sanitary Appliances - Western Water Closets
GSO 2084:2010
Gulf Standard
Design and application of speed control humps
GSO 440:2007
Gulf Standard
Calcium Silicate bricks
Recently Published from Construction and Building Sector
GSO ISO 52000-3:2024
ISO 52000-3:2023
Gulf Standard
Energy performance of buildings
— Overarching EPB assessment
— Part 3: General principles for determination and reporting of primary energy factors (PEF) and CO2 emission coefficients
GSO EN 1634-3:2024
EN 1634-3:2004
Gulf Standard
Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 3: Smoke control test for door and shutter assemblies
GSO ISO/TR 52016-2:2024
ISO/TR 52016-2:2017
Gulf Standard
Energy performance of buildings
— Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads
— Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1
GSO ASTM C1354/C1354M:2024
ASTM C1354/C1354M:22
Gulf Standard
Standard Test Method for Strength of Individual Stone Anchorages in Dimension Stone