GSO ASTM E2397/E2397M:2024
ASTM E2397/E2397M:19
Gulf Standard
Current Edition
·
Approved on
25 April 2024
Standard Practice for Determination of Dead Loads and Live Loads Associated with Vegetative (Green) Roof Systems
GSO ASTM E2397/E2397M:2024 Files
No files for this standard are available in the store currently.
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
GSO ASTM E2397/E2397M:2024 Scope
1.1 This practice covers a standardized procedure for predicting the system weight of a vegetative (green) roof system.
1.2 The practice addresses the loads associated with vegetative (green) roof systems. Components that are typically
encountered in vegetative (green) roof systems include:
membranes, non-absorptive plastic sheet components, metallic
layers, fabrics, Geo composite drain layers, synthetic reinforcing layers, cover/recover boards, insulation materials, growth
media, granular drainage media, and plant materials.
1.3 This practice also addresses the weight of the vegetative
(green) roof system under two conditions: (1) weight under
drained conditions after new water additions by rainfall or
irrigation have ceased (this includes the weight of retained
water and captured water), and (2) weight when rainfall or
irrigation is actively occurring and the drain layer is completely
filled with water. The first condition is considered the dead load
of the vegetative (green) roof system. The difference in weight
between the first and second conditions, approximated by the
weight of transient water in the drain layer, is considered a live
load.
1.4 This practice does not address point or line loads
associated with architectural elements that are not essential
components of a particular vegetative (green) roof system.
These architectural elements may include pavement, walls, and
masonry, and so forth.
1.5 This practice does not address live loads associated with
construction activities.
1.6 This practice does not address loads associated with
snow or wind.
1.7 The values stated in either SI units or inch-pound units
are to be regarded separately as standard. The values stated in
each system may not be exact equivalents; therefore, each
system shall be used independently of the other. Combining
values from the two systems may result in non-conformance
with the standard.
1.8 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and to
determine the applicability of regulatory limitations prior to
use.
1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee.
Best Sellers From Construction and Building Sector
GSO 1431:2002
Gulf Technical Regulation
Sanitary appliances - pressurized flushing devices
GSO 1427:2008
Gulf Standard
Ceramic Sanitary Appliances - Western Water Closets
GSO 1421:2002
Gulf Technical Regulation
Hollow blocks made from clay for walls
GSO 440:2007
Gulf Standard
Calcium Silicate bricks
Recently Published from Construction and Building Sector
GSO 113:1989
Gulf Standard
TECHNICAL TERMS AND DEFINITIONS USED
IN SPINNING AND WEAVING INDUSTRY
PART 2: FABRIC DEFECTS
GSO ASTM C915:2025
ASTM C915:25
Gulf Standard
Standard Specification for Precast Reinforced Concrete Crib Wall Members
GSO ASTM E1186:2025
ASTM E1186:22
Gulf Standard
Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Barrier Systems
GSO EN 13172:2025
EN 13172:2024
Gulf Standard
Thermal insulation products - Common evaluation rules