GSO ISO 25539-3:2024 Scope

ISO 25539-3:2011 specifies requirements for vena cava filters, based upon current medical knowledge. With regard to safety, it gives requirements for intended performance, design attributes, materials, design evaluation, manufacturing, sterilization, packaging and information supplied by the manufacturer. ISO 25539-3:2011 supplements ISO 14630, which specifies general requirements for the performance of non-active surgical implants.

The following are within the scope of ISO 25539-3:2011:

  • vena cava filters used to prevent pulmonary embolism by mechanical filtration in the inferior vena cava: while ISO 25539-3:2011 might be useful with respect to filters implanted in other venous locations (e.g. superior vena cava, iliac veins), it does not specifically address use of filters in other implantation sites;
  • sheath/dilator kits, providing that they comprise an integral component of the access, delivery or retrieval/conversion of the vena cava filter.
  • delivery systems, providing that they comprise an integral component of the deployment of the vena cava filter.
  • optional filters that can be retrieved or converted, and permanent filters together with their associated endovascular systems: while ISO 25539-3:2011 might be useful with respect to the evaluation of repositioning filters after chronic implantation, it does not specifically address filter repositioning.

The following are outside the scope of ISO 25539-3:2011:

  • temporary filters (e.g. tethered) that need to be removed after a defined period of time;
  • coatings, surface modifications, and/or drugs;
  • issues associated with viable tissues and non-viable biological materials;
  • degradation and other time-dependent aspects of absorbable materials;
  • procedures and devices (e.g. venous entry needle) used prior to the vena cava filter procedure.

Best Sellers From Health Sector

GSO 2017:2023
 
Gulf Standard
Personal Care and Baby Wet Wipes
YSMO GSO 2017:2023
GSO 2017:2023 
Yemeni Standard
Personal Care and Baby Wet Wipes
GSO 2241:2023
 
Gulf Standard
Cosmetic Products - Body Cleaners
GSO 1223:2023
 
Gulf Standard
Cosmetic Products-Deodorants

Recently Published from Health Sector

GSO ASTM F404:2026
ASTM F404:21 
Gulf Standard
Standard Consumer Safety Specification for High Chairs
GSO ISO 24806:2026
ISO 24806:2023 
Gulf Standard
Recreational diving services — Requirements for rebreather diver training — Decompression diving to 60 m
GSO ISO 23223:2026
ISO 23223:2025 
Gulf Standard
Alpine ski boots with improved walking soles — Interface with alpine ski-bindings — Requirements, test methods and marking
GSO ASTM F2236:2026
ASTM F2236:24 
Gulf Standard
Standard Consumer Safety Specification for Soft Infant and Toddler Carriers