GSO ASTM D4718/D4718M:2022 Scope
1.1 This practice presents a procedure for calculating the
unit weights and water contents of soils containing oversize
particles when the data are known for the soil fraction with the
oversize particles removed.
1.2 This practice also can be used to calculate the unit
weights and water contents of soil fractions when the data are
known for the total soil sample containing oversize particles.
1.3 This practice is based on tests performed on soils and
soil-rock mixtures in which the portion considered oversize is
that fraction of the material retained on the 4.75-mm [No. 4]
sieve. Based on these tests, this practice is applicable to soils
and soil-rock mixtures in which up to 40 % of the material is
retained on the 4.75-mm [No. 4] sieve. The practice also is
considered valid when the oversize fraction is that portion
retained on some other sieve, but the limiting percentage of
oversize particles for which the correction is valid may be
lower. However, the practice is considered valid for materials
having up to 30 % oversize particles when the oversize fraction
is that portion retained on the 19-mm [3⁄4-in.] sieve.
1.4 The factor controlling the maximum permissible percentage of oversize particles is whether interference between
the oversize particles affects the unit weight of the finer
fraction. For some gradations, this interference may begin to
occur at lower percentages of oversize particles, so the limiting
percentage must be lower for these materials to avoid inaccuracies in the computed correction. The person or agency using
this practice shall determine whether a lower percentage is to
be used.
1.5 This practice may be applied to soils with any percentage of oversize particles subject to the limitations given in 1.3
and 1.4. However, the correction may not be of practical
significance for soils with only small percentages of oversize
particles. The person or agency specifying this practice shall
specify a minimum percentage of oversize particles below
which the practice need not be applied. If a minimum percentage is not specified, 5 % shall be used.
Best Sellers From Construction and Building Sector
GSO 1431:2002
Gulf Technical Regulation
Sanitary appliances - pressurized flushing devices

GSO 1427:2008
Gulf Standard
Ceramic Sanitary Appliances - Western Water Closets

GSO 1421:2002
Gulf Technical Regulation
Hollow blocks made from clay for walls

GSO 2084:2010
Gulf Standard
Design and application of speed control humps

Recently Published from Construction and Building Sector
GSO ASTM C110:2024
ASTM C110:24
Gulf Standard
Standard Test Methods for Physical Testing of Quicklime, Hydrated Lime, and Limestone


GSO ISO 12911:2024
ISO 12911:2023
Gulf Standard
Organization and digitization of information about buildings and civil engineering works, including building information modelling (BIM) — Framework for specification of BIM implementation


GSO ASTM C163:2024
ASTM C163:05(2023)
Gulf Standard
Standard Practice for Mixing Thermal Insulating Cement Samples


GSO EN 13501-2:2024
EN 13501-2:2023
Gulf Standard
Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance and/or smoke control tests, excluding ventilation services