GSO ISO 30011:2017
ISO 30011:2010
Gulf Standard
Current Edition
·
Approved on
03 October 2017
Workplace air -- Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma mass spectrometry
GSO ISO 30011:2017 Files
English
34 Pages
Current Edition
Reference Language
180.19 USD
GSO ISO 30011:2017 Scope
This International Standard specifies a procedure for the use of quadrupole inductively coupled plasma mass spectrometry (ICP-MS) for analysing test solutions prepared from samples of airborne particulate matter collected as specified in ISO 15202-1. Method development, performance checks, and a routine analysis method are specified.
Test solutions for analysis by this International Standard are prepared as specified in ISO 15202-2.
This International Standard is applicable to the assessment of workplace exposure to metals and metalloids for comparison with limit values (see e.g. EN 689[10], ASTM E1370[8]).
The following is a non-exclusive list of metals and metalloids for which limit values have been set (see Reference [15]) and for which one or more of the sample preparation methods specified in ISO 15202-2 and the analytical procedure described in this International Standard are applicable. However, there is no information available on the effectiveness of any of these sample preparation methods for those elements listed in italics.
aluminium caesium lead platinum tungsten
antimony chromium lithium potassium uranium
arsenic cobalt magnesium rhodium vanadium
barium copper manganese selenium yttrium
beryllium gallium mercury silver zinc
bismuth germanium molybdenum sodium zirconium
boron hafnium nickel tellurium
cadmium indium niobium thallium
calcium iron phosphorus tin
This International Standard is not applicable to determination of elemental mercury, since mercury vapour is not collected using the sampling method specified in ISO 15202-1.
The procedure is suitable for assessment of exposure against the long-term exposure limits for most of the metals and metalloids listed above when sampling at a typical flow rate of 2 l min−1 for sampling times in the range 0,5 h to 8 h and for assessment of exposure against the short-term exposure limits, where applicable.
The procedure is subject to no significant spectral interferences (see A.3), provided that suitable analytical isotopes are used. However, inadequate matrix-matching can adversely affect results.
Best Sellers From Chemical and Textile Sector
GSO 1943:2024
Gulf Technical Regulation
Cosmetic Products – Safety Requirements of Cosmetics and Personal Care Products

GSO 151:2022
Gulf Standard
Synthetic Detergents –Household Synthetic Detergents Powder

GSO 575:2016
Gulf Standard
Facial tissue - paper

GSO 2555:2021
Gulf Technical Regulation
General Safety Requirements of Household Detergents

Recently Published from Chemical and Textile Sector
YSMO GSO 802:2024
GSO 802:2023
Yemeni Standard
Sodium Hypochlorite Solution for Domestic Uses


YSMO GSO 2716:2024
GSO 2716:2023
Yemeni Standard
Adult Diapers for Single-Use


YSMO GSO 1217:2024
GSO 1217:2022
Yemeni Standard
Cosmetic products – Hair oils


GSO ISO 5631-3:2024
ISO 5631-3:2022
Gulf Standard
Paper and board — Determination of colour by diffuse reflectance — Part 3: Indoor illumination conditions (D50/2°)