GSO ISO 16017-1:2016

ISO 16017-1:2000
Gulf Standard   Current Edition · Approved on 22 December 2016

Indoor, ambient and workplace air -- Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography -- Part 1: Pumped sampling

GSO ISO 16017-1:2016 Files

English 32 Pages
Current Edition Reference Language
169.56 USD

GSO ISO 16017-1:2016 Scope

This part of ISO 16017 gives general guidance for the sampling and analysis of volatile organic compounds (VOCs) in air. It is applicable to ambient, indoor and workplace atmospheres and the assessment of emissions from materials in small- or full-scale test chambers. This part of ISO 16017 is appropriate for a wide range of VOCs, including hydrocarbons, halogenated hydro­carbons, esters, glycol ethers, ketones and alcohols. A number of sorbents 1) are recommended for the sampling of these VOCs, each sorbent having a different range of applicability. Very polar compounds will generally require derivatization, very low boiling compounds will only be partially retained by the sorbents, depending on ambient temperature, and can only be estimated qualitatively. Semi-volatile compounds will be fully retained by the sorbents, but may only be partially recovered. Compounds for which this part of ISO 16017 has been tested are given in tables. This part of ISO 16017 may be applicable to compounds not listed, but in these cases it is advisable to use a back-up tube containing the same or a stronger sorbent. This part of ISO 16017 is applicable to the measurement of airborne vapours of VOCs in a concentration range of approximately 0,5 mg/ m3 to 100 mg/m3 individual compound. The upper limit of the useful range is set by the sorptive capacity of the sorbent used and by the linear dynamic range of the gas chromatograph column and detector or by the sample-splitting capability of the analytical instrumentation used. The sorptive capacity is measured as a breakthrough volume of air, which determines the maximum air volume that shall not be exceeded when sampling. The lower limit of the useful range depends on the noise level of the detector and on blank levels of analyte and/or interfering artefacts on the sorbent tubes. Artefacts are typically sub-nanogram for well-conditioned Tenax GR and carbonaceous sorbents such as Carbopack/Carbotrap type materials, carbonized molecular sieves and molecular sieves such as Spherocarb, or pure charcoal; at low nanogram levels for Tenax TA and at 5 ng to 50 ng levels for other porous polymers such as Chromosorbs and Porapaks. Sensitivity is typically limited to 0,5 μg/m3 for 10-litre air samples with this latter group of sorbents because of their inherent high background. The procedure specified in this part of ISO 16017 is applicable to low flowrate personal sampling pumps and gives a time-weighted average result. It is not applicable to the measurement of instantaneous or short-term fluctuations in concentration.

Best Sellers From Chemical and Textile Sector

GSO 1943:2024
 
Gulf Technical Regulation
Cosmetic Products – Safety Requirements of Cosmetics and Personal Care Products
GSO 575:2016
 
Gulf Standard
Facial tissue - paper
GSO 151:2022
 
Gulf Standard
Synthetic Detergents –Household Synthetic Detergents Powder
GSO 2640:2021
 
Gulf Standard
Cosmetic Products - General Requirements of Soaps

Recently Published from Chemical and Textile Sector

GSO ISO 18692-1:2024
ISO 18692-1:2018 
Gulf Standard
Fibre ropes for offshore stationkeeping — Part 1: General specification
GSO ASTM F791:2024
ASTM F791:18(2023) 
Gulf Standard
Standard Test Method for Stress Crazing of Transparent Plastics
GSO ISO 19408:2024
ISO 19408:2023 
Gulf Standard
Footwear — Sizing — Vocabulary
GSO ISO 1407:2024
ISO 1407:2023 
Gulf Standard
Rubber — Determination of solvent extract