GSO IEC 60601-1-10:2015

IEC 60601-1-10:2007
Gulf Standard   Current Edition · Approved on 03 September 2015

Medical electrical equipment - Part 1-10: General requirements for basic safety and essential performance - Collateral Standard: Requirements for the development of physiologic closed-loop controllers

GSO IEC 60601-1-10:2015 Files

English 79 Pages
Current Edition Reference Language

GSO IEC 60601-1-10:2015 Scope

This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS. This collateral standard specifies requirements for the development (analysis, design,VERIFICATION and VALIDATION) of a PHYSIOLOGIC CLOSED-LOOP CONTROLLER (PCLC) as part of a PHYSIOLOGIC CLOSED-LOOP CONTROL SYSTEM (PCLCS) in ME EQUIPMENT and ME SYSTEMS to control a PHYSIOLOGIC VARIABLE. NOTE A PHYSIOLOGIC VARIABLE can be a body chemistry (e.g. electrolytes, blood glucose), a physical property (e.g. PATIENT temperature, electrophysiologic, hemodynamic), or a pharmaceutical concentration. This collateral standard applies to various types of PCLC, e.g. linear and non-linear, adaptive, fuzzy, neural networks. This collateral standard does not specify: _ additional mechanical requirements; or _ additional electrical requirements. This collateral standard applies to a closed-loop controller (see Figure 1) that sets the CONTROLLER OUTPUT VARIABLE in order to adjust (i.e., change or maintain) the measured PHYSIOLOGIC VARIABLE by relating it to the REFERENCE VARIABLE. A closed-loop controller that maintains a physical or chemical VARIABLE, using feedback that is not measured from a PATIENT, is outside the scope of this standard.

Best Sellers From Health Sector

GSO 2017:2023
 
Gulf Standard
Personal Care and Baby Wet Wipes
YSMO GSO 2017:2023
GSO 2017:2023 
Yemeni Standard
Personal Care and Baby Wet Wipes
GSO 2241:2023
 
Gulf Standard
Cosmetic Products - Body Cleaners
GSO 1223:2023
 
Gulf Standard
Cosmetic Products-Deodorants

Recently Published from Health Sector

GSO EN 1273:2020+A1:2026
EN 1273:2020+A1:2023 
Gulf Standard
Child care articles - Baby walking frames - Safety requirements and test methods
GSO CEN/TR 16467:2026
CEN/TR 16467:2013 
Gulf Standard
Playground equipment accessible for all children
GSO ASTM F1816:2026
ASTM F1816:18(2024) 
Gulf Standard
Standard Safety Specification for Drawstrings on Children's Upper Outerwear
GSO ASTM F2194:2026
ASTM F2194:25 
Gulf Standard
Standard Consumer Safety Specification for Bassinets and Cradles