Radiation protection instrumentation - Monitoring equipment - Radioactive aerosols in the environment

GSO IEC 61172:2015 Files

English 83 Pages
Current Edition Reference Language

GSO IEC 61172:2015 Scope

This International Standard is applicable to transpo rtable or installed equipment for continuous monitoring of radioactive aerosol in the environment for both normal and accident conditions. For the purpose of this standard, monitoring includes the continuous sample collection with, if desired, the capability to automatically initiate sampling. In particular the standard is applicable to equipments designed to fulfil the following functions: - The determination of the activity per unit volume of radionuclides in the form of aerosols, either per unit time together with the variations as a function of time, or integrated over a longer time period, e.g. 24 h and measurement of the volume sampled. - The actuation of an alarm signal when either a predetermined high concentration or a predetermined time integrated concentration of an aerosol activity is exceeded. The aerosol monitoring can be made both by continuous measurements during sampling and by measurement after collection of the sample. In the measurement after collection, the sample is removed from the air sampler and analysed in a laboratory. This procedure of measurement has to be followed in special cases such as the activity assessment of specific radionuclides and is not within the scope of this standard. The continuous method of measurement is the more widely used and consists in collecting the radioactive samples by drawing air through a filter and measuring the aerosol activity accumulated on it with a detector which is close to the filter. The filters are suitably chosen and periodically changed according to the conditions of use. In some cases automatic filter sequences are used to avoid the build-up of radioactivity or excess of dust on the filter. Also the type of detectors depends on the various conditions such as the type of radiation, its energy and the level of activity. The discrimination against natural radioactivity (such as airborne radon and thoron daughters) can be an impo rtant problem in monitoring low-level radioactivity in air especially with transuranic elements.

Best Sellers From Electrical Sector

YSMO GSO 2530:2023
GSO 2530:2016 
Yemeni Technical Regulation
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines

Recently Published from Electrical Sector

GSO IEC PAS 63629:2026
IEC PAS 63629:2025 
Gulf Standard
PSR – Specific rules for luminaires
GSO IEC 60704-2-3:2026
IEC 60704-2-3:2025 
Gulf Standard
Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 2-3: Particular requirements for dishwashers
GSO IEC 60270:2026
IEC 60270:2025 
Gulf Standard
High-voltage test techniques – Charge-based measurement of partial discharges
GSO IEC 60227-5:2026
IEC 60227-5:2024 
Gulf Standard
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables (cords)