GSO IEC 61582:2015

IEC 61582:2004
Gulf Standard   Current Edition · Approved on 03 September 2015

Radiation protection instrumentation - In vivo counters - Classification, general requirements and test procedures for portable, transportable and installed equipment

GSO IEC 61582:2015 Files

English 123 Pages
Current Edition Reference Language

GSO IEC 61582:2015 Scope

This International Standard specifies the classification, general design requirements, performance characteristics and test procedures for in vivo counting systems for detecting trace amounts of radionuclides in the bodies of persons working in nuclear power plants, laboratories and facilities handling radionuclides, and inhabitants living on territory which may be contaminated by either naturally occurring or artificial radionuclides. The purpose is to determine the dose equivalent to organs and the effective dose of internal radiation for the whole body. This standard is applicable both to equipment with spectroscopic capabilities and instruments for rapid screening for gross internal contamination only. This standard is applicable to instruments for the monitoring of certain critical organs (for example, lungs, thyroid gland, etc.) as well as instruments for monitoring the whole body. The standard applies to equipment for the measurement of the activity of gamma-emitting radionuclides in humans in order to determine the committed dose equivalent due to internal contamination in accordance with the recommendations of the ICRP 60 and ICRP 61. The requirements of the standard are applicable to the installed apparatus, to vehiclemounted equipment and to portable instruments. However, Annex B defines the additional mechanical and environmental performance requirements and the additional testing required for transportable and portable assemblies. The general and radiological requirements of all types of in vivo counters are included in this standard. Depending on the type of instrument and the organ to be checked, measurement geometry may require the subject of the monitoring procedure to stand, sit, or lie. The detection assembly includes one or more radiation detector. Normally, these are shielded-scintillation or semi-conductor detectors. Where identification of the location of contamination is required, the detectors may be collimated. The measurement assembly includes functional units for the processing of signals from the detection assembly as well as units for the display of the measured activity. For the measurement of body mass a built-in weighing machine may be used.

Best Sellers From Electrical Sector

YSMO GSO 2530:2023
GSO 2530:2016 
Yemeni Technical Regulation
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines

Recently Published from Electrical Sector

GSO IEC 63522-32:2026
IEC 63522-32:2025 
Gulf Standard
Electrical relays - Tests and measurements - Part 32: Acoustic noise
GSO IEC 61362:2026
IEC 61362:2024 
Gulf Standard
Guidelines to specification of hydraulic turbine governing systems
GSO IEC TS 62271-313:2026
IEC TS 62271-313:2025 
Gulf Standard
High-voltage switchgear and controlgear - Part 313: Direct current circuit-breakers
GSO IEC TR 63411:2026
IEC TR 63411:2025 
Gulf Standard
Grid connection of offshore wind via VSC-HVDC systems