GSO IEC 61526:2015

IEC 61526:2010
Gulf Standard   Current Edition · Approved on 03 September 2015

Radiation protection instrumentation - Measurement of personal dose equivalents Hp(10) and Hp(0,07) for X, gamma, neutron and beta radiations - Direct reading personal dose equivalent meters

GSO IEC 61526:2015 Files

English 119 Pages
Current Edition Reference Language

GSO IEC 61526:2015 Scope

This International Standard applies to personal dose equivalent meters with the following characteristics: a) They are worn on the trunk or the extremities of the body. b) They measure the personal dose equivalents Hp(10) and Hp(0,07) from external X and gamma, neutron and beta radiations, and may measure the personal dose equivalent rates H& p () 10 and H& p ( ) 0,07 . c) They have a digital indication. d) They may have alarm functions for the personal dose equivalents or personal dose equivalent rates. This standard is therefore applicable to the measurement of the following combinations of dose quantities (including the respective dose rates) and radiation 1) Hp(10) and Hp(0,07) from X and gamma radiations; 2) Hp(10) and Hp(0,07) from X, gamma and beta radiations; 3) Hp(10) from X and gamma radiations; 4) Hp(10) from neutron radiations; 5) Hp(10) from X, gamma and neutron radiations; 6) Hp(0,07) from X, gamma and beta radiations. NOTE 1 When reference is made in this standard to ”dose”, this is meant to indicate personal dose equivalent, unless otherwise stated. NOTE 2 When reference is made in this standard to ”dosemeter”, this is meant to include all personal dose equivalent meters, unless otherwise stated. This standard specifies requirements for the dosemeter and, if supplied, for its associated readout system. This standard specifies, for the dosemeters described above, general characteristics, general test procedures, radiation characteristics as well as electrical, mechanical, safety and environmental characteristics. The only requirements specified for associated readout systems are those which affect its accuracy of readout of the personal dose equivalent and alarm settings and those which concern the influence of the reader on the dosemeter. This standard also specifies in Annex C usage categories with respect to different measuring capabilities. This standard does not cover special requirements for accident or emergency dosimetry although the dosemeters may be used for this purpose. The standard does not apply to dosemeters used for measurement of pulsed radiation, such as radiation emanating from most medical diagnostic X-ray facilities, linear accelerators or similar equipment.

Best Sellers From Electrical Sector

YSMO GSO 2530:2023
GSO 2530:2016 
Yemeni Technical Regulation
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines

Recently Published from Electrical Sector

GSO ISO 20816-21:2026
ISO 20816-21:2025 
Gulf Standard
Mechanical vibration — Measurement and evaluation of machine vibration — Part 21: Horizontal axis wind turbines
GSO CEN/TR 16999:2026
CEN/TR 16999:2019 
Gulf Standard
Solar energy systems for roofs - Requirements for structural connections to solar panels
GSO IEC 60884-2-7:2026
IEC 60884-2-7:2025 
Gulf Standard
Plugs and socket-outlets for household and similar purposes - Part 2-7: Particular requirements for cord extension sets
GSO IEC TR 63411:2026
IEC TR 63411:2025 
Gulf Standard
Grid connection of offshore wind via VSC-HVDC systems