GSO IEC 61168:2014
IEC 61168:1993
Gulf Standard
Current Edition
·
Approved on
25 December 2014
Radiotherapy simulators - Functional performance characteristics
GSO IEC 61168:2014 Files
English
63 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
GSO IEC 61168:2014 Scope
This International Standard applies to RADIOTHERAPY SIMULATORS which use diagnostic
X-RAY EQUIPMENT tO geometrically simulate a RADIOTHERAPY RADIATION BEAM SO that the
TREATMENT VOLUME to be irradiated during RADIOTHERAPY can be localized and the position
and size of the therapeutic RADIATION FIELD can be confirmed.
This standard applies to RADIOTHERAPY SIMULATORS using HIGH VOLTAGE GENERATORS
operating at a voltage not exceeding 400 kV complying with IEC 601-2-7.
This standard applies to RADIOTHERAPY SIMULATORS intended exclusively for RADIOTHERAPY
simulation as a prelude to intended RADIOTHERAPY and not for any other purposes such as
general diagnostic purposes.
The requirements in this standard are based on the assumption that the RADIOTHERAPY
SIMULATOR consists of:
a) a system for producing a beam of X-RADIATION not exceeding 400 kV which
simulates the geometry of the RADIOTHERAPY RADIATION BEAM;
b) a system for producing images of the transmitted X-RAY BEAM, either by
RADIOGRAPHY Or by RADIOSCOPY;
c) an assembly which controls the size of the RADIATION BEAM and which delineates the
intended treatment area;
d) a mechanical structure that physically simulates the geometry and motions of a
RADIOTHERAPY EQUIPMENT, and which suppo rts an imaging system;
e) a PATIENT SUPPORT system.
This standard applies to EQUIPMENT intended for use under the supe rv ision of a QUALIFIED
PERSON.
Except where otherwise stated this standard assumes that the RADIOTHERAPY SIMULATOR
has an ISOCENTRIC GANTRY with no pitch or roll movement of the RADIATION HEAD.
This standard specifies TYPE TESTS to be performed by the MANUFACTURER at the design
and construction stages of a RADIOTHERAPY SIMULATOR but does not specify SITE TESTS t0
be performed after installation at the USER'S site. The accompanying technical report
IEC 1170, however, does suggest that many of the test procedures are appropriate for
SITE TESTS.
During the course of any test procedure only those adjustments of the RADIOTHERAPY
SIMULATOR are permissible that can be carried out using controls normally accessible to
the OPERATOR and which are regarded as forming part of the normal operation of the
RADIOTHERAPY SIMULATOR.
Best Sellers From Electrical Sector
YSMO GSO 2530:2023
GSO 2530:2016
Yemeni Technical Regulation
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
Recently Published from Electrical Sector
GSO IEC 61362:2026
IEC 61362:2024
Gulf Standard
Guidelines to specification of hydraulic turbine governing systems
GSO IEC TS 62271-313:2026
IEC TS 62271-313:2025
Gulf Standard
High-voltage switchgear and controlgear - Part 313: Direct current circuit-breakers
GSO IEC 61643-41:2026
IEC 61643-41:2025
Gulf Standard
Low-voltage surge protective devices - Part 41: Surge protective devices connected to DC low-voltage power systems – Requirements and test methods
GSO IEC TS 62600-100:2026
IEC TS 62600-100:2024
Gulf Standard
Marine energy - Wave, tidal and other water current converters - Part 100: Electricity producing wave energy converters - Power performance assessment