GSO IEC 61058-2-1:2014

IEC 61058-2-1:2010
Gulf Standard   Current Edition · Approved on 25 December 2014

Switches for appliances - Part 2-1: Particular requirements for cord switches

GSO IEC 61058-2-1:2014 Files

GSO IEC 61058-2-1:2014 Scope

This clause of Part 1 is applicable except as follows: 1.1 Replacement: 1.1 This International Standard applies to cord switches (mechanical or electronic) for appliances actuated by hand, by foot or by other human activity, to operate or control electrical appliances and other equipment for household or similar purposes with a rated voltage not exceeding 250 V and a rated current not exceeding 16 A. These switches are intended to be operated by a person, via an actuating member or by actuating a sensing unit. The actuating member or sensing unit can be integral or arranged separately from the switch. The transmission of a signal between the actuating member or sensing unit and the switch may be made either physically or electrically (for example electrical, optical, acoustic or thermal). Switches which incorporate additional control functions governed by the switch function are within the scope of this standard. This standard also covers the indirect actuation of the switch when the operation of the actuating member or sensing unit is provided by a remote control or a part of an appliance or equipment such as a door. NOTE 1 Electronic switches may be combined with mechanical switches giving full disconnection or microdisconnection. NOTE 2 Electronic switches without a mechanical switch in the supply circuit provide only electronic disconnection. Therefore, the circuit on the load side is always considered to be live. NOTE 3 For switches used in tropical climates, additional requirements may be necessary. NOTE 4 Attention is drawn to the fact that the standards for appliances may contain additional or alternative requirements for switches. NOTE 5 Throughout this standard, the word “appliance” means “appliance or equipment”. 1.2 Replacement: 1.2 This standard applies to switches intended to be connected to a flexible cable." NOTE In this document, the word “cable” means “cable or cord”. 1.3 This subclause applies. 1.4 This subclause does not apply.

Best Sellers From Electrical Sector

YSMO GSO 2530:2023
GSO 2530:2016 
Yemeni Technical Regulation
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines

Recently Published from Electrical Sector

GSO 2770:2024
 
Gulf Standard
WATER HEATERS - ENERGY PERFORMANCE REQUIREMENTS
GSO IEC 63027:2024
IEC 63027:2023 
Gulf Standard
Photovoltaic power systems - DC arc detection and interruption
GSO IEC 60885-3:2024
IEC 60885-3:2015 
Gulf Standard
Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables
GSO IEC TS 62257-9-2:2024
IEC TS 62257-9-2:2016 
Gulf Standard
Recommendations for renewable energy and hybrid systems for rural electrification - Part 9-2: Integrated systems - Microgrids