GSO IEC 60947-7-2:2014 Scope

This part of IEC 60947 specifies requirements for protective conductor terminal blocks with PE function up to 120 mm2 (250 kcmil) and for protective conductor terminal blocks with PEN function equal to and above 10 mm2 (AWG 8) with screw-type or screwless-type clamping units, primarily intended for industrial applications. NOTE AWG is the abbreviation of “American Wire Gage” [Gage (US) = Gauge (UK)] kcmil = 1 000 cmil 1 cmil = 1 circular mil = surface of a circle having a diameter of 1 mil 1 mil = 1/1 000 inch Protective conductor terminal blocks are used to form the electrical and mechanical connection between copper conductors and the fixing support. lt is applicable to protective conductor terminal blocks for the connection of round copper conductors with or without special preparation having a cross-section between 0,2 mm2 and 120 mm2 (AWG 24 and 250 kcmil), intended to be used in circuits of a rated voltage not exceeding 1 000 V a.c. up to 1 000 Hz or 1 500 V d.c., most commonly in conjunction with terminal blocks according to IEC 60947-7-1. This standard may be used as guide for − protective conductor terminal blocks requiring the fixing of special devices to the conductors, for example quick connect terminations or wrapped connections, etc.; – protective conductor terminal blocks providing direct contact to the conductors by means of edges or points penetrating the insulation, for example insulation displacement connections, etc. Where applicable in this standard, the term “clamping unit” has been used instead of the term “terminal”. This is taken into account in case of reference to IEC 60947-1.

Best Sellers From Electrical Sector

YSMO GSO 2530:2023
GSO 2530:2016 
Yemeni Technical Regulation
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines

Recently Published from Electrical Sector

GSO IEC 60227-5:2026
IEC 60227-5:2024 
Gulf Standard
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables (cords)
GSO IEC TS 62600-301:2026
IEC TS 62600-301:2019 
Gulf Standard
Marine energy - Wave, tidal and other water current converters - Part 301: River energy resource assessment
GSO IEC TS 62600-10:2026
IEC TS 62600-10:2021 
Gulf Standard
Marine energy - Wave, tidal and other water current converters - Part 10: Assessment of mooring system for marine energy converters (MECs)
GSO IEC 62933-4-2:2026
IEC 62933-4-2:2025 
Gulf Standard
Electric energy storage (EES) systems – Part 4-2: Guidance on environmental issues – Assessment of the environmental impact of battery failure in an electrochemical based storage system