GSO IEC 62640:2014
IEC 62640:2011
Gulf Standard
Current Edition
·
Approved on
25 December 2014
Residual current devices with or without overcurrent protection for socket-outlets for household and similar uses
GSO IEC 62640:2014 Files
English
267 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
GSO IEC 62640:2014 Scope
This International Standard applies to residual current-operated devices (RCD) incorporated
in, or specifically intended for use with two pole socket-outlets, with or without earthing
contact for household and similar uses (SRCD: socket-outlet residual current devices).
SRCDs, according to this standard, are intended to be used in single phase systems such as
phase to neutral or phase to phase or phase to earthed middle conductor.
SRCDs are only intended to provide additional protection downstream of the SRCD. SRCDs
are intended for use in circuits where the fault protection (indirect contact protection) is
already assured upstream of the SRCD.
NOTE 1 For example, fault protection (indirect contact protection) can be covered as follows:
– in TT systems, by upstream RCBOs or RCCBs according to IEC 61008-1 and IEC 61009-1;
– in a TN system, an overcurrent protective device can be used upstream.
NOTE 2 In the United States, there is no requirement for providing indirect contact protection upstream of an
SRCD.
NOTE 3 In Switzerland these devices are not allowed for protective measures according to the national
installation rules.
SRCDs are neither intended to provide an isolation function nor intended to be used in IT
systems.
NOTE 4 For SRCDs intended to provide isolation or fault protection, or to be used in IT systems, IEC 61008-1 or
IEC 61009-1 should be used, as applicable, in conjunction with IEC 60884-1.
NOTE 5 Requirements and testing for SRCDs intended to be used in IT systems are under consideration.
SRCDs are not used in distribution boards. They are not intended for the protection of a
complete distribution circuit or a complete final circuit. These products are intended to be
installed
– in boxes in compliance with IEC 60670-1,
– or in cable trunking systems in compliance with the IEC 61084 series,
– or in power track systems in compliance with the IEC 61534 series,
– or in boxes according to one of the above standards adjacent to socket-outlet boxes.
They are not intended to be used in enclosures or distribution boards in conformity with
IEC 60670-24, IEC 61439-1 or IEC 60439-3.
RCDs for household and similar use not covered by the scope of this standard are covered by
IEC 61008-1 or IEC 61009-1. SRCDs energized from batteries, or a circuit other than the one
powering the loads, are not covered by this standard.
The residual current device incorporates the functions of detection of the residual current, of
comparison of the value of this current with the residual operating value and of opening the
protected circuit when the residual current exceeds this value.
The maximum rated residual operating current is 30 mA.
The maximum rated current is 16 A for devices with a rated voltage not exceeding 250 V a.c.
or 20 A for devices with a rated voltage not exceeding 130 V a.c.
NOTE 6 In Australia and New Zealand, the maximum rated current for devices with a rated voltage not exceeding
250 V a.c. is 20 A.
NOTE 7 In Korea, the maximum rated current for devices with a rated voltage not exceeding 250 V a.c. is 32 A.
This International Standard applies to SRCDs incorporating overload or overcurrent
protection.
This standard also applies to a connection unit incorporating a residual current device
intended to protect only one piece of fixed electrical equipment immediately adjacent to the
connection unit (e.g. hand dryer, water cooler, etc).
NOTE 8 SRCDs are designed to be operated by uninstructed persons and not to require maintenance.
The requirements of this standard apply for normal conditions of temperature and
environment. Additional requirements may be necessary for devices used in locations having
more severe environmental conditions.
The socket-outlet part of an SRCD is covered by IEC 60884-1 or the national requirements of
the country where the SRCD is placed on the market.
Best Sellers From Electrical Sector
YSMO GSO 2530:2023
GSO 2530:2016
Yemeni Technical Regulation
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
Recently Published from Electrical Sector
GSO IEC 61362:2026
IEC 61362:2024
Gulf Standard
Guidelines to specification of hydraulic turbine governing systems
GSO IEC TS 62271-313:2026
IEC TS 62271-313:2025
Gulf Standard
High-voltage switchgear and controlgear - Part 313: Direct current circuit-breakers
GSO IEC 61643-41:2026
IEC 61643-41:2025
Gulf Standard
Low-voltage surge protective devices - Part 41: Surge protective devices connected to DC low-voltage power systems – Requirements and test methods
GSO IEC TS 62600-100:2026
IEC TS 62600-100:2024
Gulf Standard
Marine energy - Wave, tidal and other water current converters - Part 100: Electricity producing wave energy converters - Power performance assessment