GSO ISO 16063-31:2013 Scope
This part of ISO 16063 specifies details of the instrumentation and methods to be used for transverse vibration sensitivity testing. It applies to rectilinear velocity and acceleration transducers.
The methods and procedures specified in this part of ISO 16063 allow the determination of the sensitivity of a transducer to vibration in the plane perpendicular to its geometric axis of sensitivity (see Annex A). Because the magnitude of this transverse sensitivity can vary with the direction of the applied vibration, the various methods determine the maximum value. Using that value, the ratio of the transverse sensitivity to the sensitivity on the geometric axis of the transducer can be calculated. In addition, the angle at which the maximum transverse sensitivity occurs can be determined.
The methods and techniques specified can be applied without re-mounting the transducer away from its mounting surface during the test, thus avoiding significant uncertainties often encountered in methods which require repeated mounting. The different methods specified use a single-axis vibration exciter, a two-axis vibration exciter or a tri-axial vibration exciter. Tri-axial vibration excitation allows the transverse sensitivity and the sensitivity on the geometric axis to be determined simultaneously, thus simulating application conditions where the transducer is exposed to multi-axial vibration.
NOTE In accelerometer designs using a bending beam, the transverse sensitivity measured without any vibration acting on the geometric axis of sensitivity of the accelerometer may considerably differ from the transverse sensitivity measured in the presence of a vibration acting on the geometric axis of sensitivity (i.e. when the bending beam is deflected by a vibration to be measured).
This part of ISO 16063 is applicable to a frequency range from 1 Hz to 5 kHz and for a dynamic range from 1 m/s2 to 1 000 m/s2 (frequency dependent) and from 1 mm/s to 1 m/s (frequency dependent). Although among all the systems specified it is possible to achieve these ranges, generally each has limitations permitting its use in much smaller ranges.
The methods specified are by comparison both to a reference transducer and to a laser interferometer.
The methods specified allow an expanded uncertainty of the transverse sensitivity (coverage factor k = 2) of 0,1 % or less to be achieved, if the expanded uncertainty is expressed as a percentage of the sensitivity of the test transducer in its sensitive axis.
Best Sellers From Metrology Sector
GSO OIML R87:2021
OIML R87:2016
Gulf Standard
Quantity of product in prepackages
GSO OIML R79:2021
OIML R79:2015
Gulf Standard
Labeling requirements for prepackages
GSO OIML R 76-1:2009
OIML R 76-1:2006
Gulf Standard
Non-automatic weighing instruments –
Part 1: Metrological and technical requirements - Tests
GSO OIML R111-1:2007
OIML R111-1:2004
Gulf Standard
Weights of classes E1, E2,F1,F2,M1,M1-2,M2,M2-3 and M3
Part 1: Metrological and Technical requirements
Recently Published from Metrology Sector
GSO ISO 23783-2:2026
ISO 23783-2:2022
Gulf Standard
Automated liquid handling systems — Part 2: Measurement procedures for the determination of volumetric performance
GSO ISO 16610-45:2026
ISO 16610-45:2025
Gulf Standard
Geometrical product specifications (GPS) — Filtration — Part 45: Morphological profile filters: Segmentation
GSO ISO 4064-1:2026
ISO 4064-1:2024
Gulf Standard
Water meters for cold potable water and hot water — Part 1: Metrological and technical requirements
GSO ISO 16610-31:2026
ISO 16610-31:2025
Gulf Standard
Geometrical product specifications (GPS) — Filtration — Part 31: Robust profile filters: Gaussian regression filters