GSO ISO 28278-2:2013

ISO 28278-2:2010
Gulf Standard   Current Edition · Approved on 09 September 2013

Glass in building -- Glass products for structural sealant glazing -- Part 2: Assembly rules

GSO ISO 28278-2:2013 Files

English 33 Pages
Current Edition Reference Language
USD 191.57

GSO ISO 28278-2:2013 Scope

This part of ISO 28278 gives guidelines for the assembly and bonding of glass elements in a frame, window, door or curtain-walling construction, or directly into the building by means of structural bonding of the glass element into or onto the framework or directly into the building. It gives the assembler information that enable him to organize his work and comply with requirements regarding quality control. Quality control of the assembly process is of the highest importance. This part of ISO 28278 provides the minimum requirements for acceptable quality control of the process of structural sealant glazing (SSG) on a single project. The annexes contained at the end of this part of ISO 28278 provide the methods to ensure proper application and documentation for a safe and weatherproof glazing assembly product. This process is intended to be applicable to most SSG projects. The project testing on metal substrates and glass products will determine proper surface preparation and installation instructions. These rules do not apply to the adhesion or durability of the paint finishes or glass products. This is not intended to be a durability test requirement for the paint and glass products commonly used in the SSG process. The structural, weatherproofing and sealant products which are commonly used in structural glazing applications are those based on organosiloxane, “silicone” polymers. This part of ISO 28278 does not preclude the use of other sealant types, where these can demonstrate suitability for service according to this part of ISO 28278 and when they are used following the recommendations of the sealant manufacturer. Supports to be taken into consideration shall be only metallic substrates, uncoated glass, coated glass and ceramic frit enamelled glass. This part of ISO 28278 relates to SSG systems for use in façades and roofs, or parts of them, with glazing with slopes as shown in Figure 1. Façades with an inclination of less than 15° from the vertical are considered vertical façades. If the slope to the outer side has an inclination above 50°, the glass is considered unsupported glass.

Best Sellers From Construction and Building Sector

GSO 1427:2008
 
Gulf Standard
Ceramic Sanitary Appliances - Western Water Closets
GSO 1431:2002
 
Gulf Technical Regulation
Sanitary appliances - pressurized flushing devices
GSO 2489:2015
 
Gulf Standard
Specifications of Recycled Aggregates from Construction Waste to be used in construction Works
GSO 2084:2010
 
Gulf Standard
Design and application of speed control humps

Recently Published from Construction and Building Sector

GSO EN 13888-1:2026
EN 13888-1:2022 
Gulf Standard
Grouts for ceramic tiles - Part 1: Requirements, classification, designation, marking and labelling
GSO ISO 679:2026
ISO 679:2009 
Gulf Standard
Cement — Test methods — Determination of strength
GSO ISO 50002-2:2026
ISO 50002-2:2025 
Gulf Standard
Energy audits — Part 2: Guidance for conducting an energy audit using ISO 50002-1 in buildings
GSO ISO 16535:2026
ISO 16535:2019 
Gulf Standard
Thermal insulating products for building applications — Determination of long-term water absorption by immersion