GSO IEC TS 62395-2:2013 Scope
This part of IEC 62395 provides detailed recommendations for the system design, installation,
maintenance and repair of electrical resistance trace heating systems in industrial and
commercial applications. This technical specification does not include or provide for any
applications in potentially explosive atmospheres.
This specification pertains to trace heating systems that may comprise either factory
constructed or field (work-site) assembled units, and which may be series heater cables,
parallel heater cables, heater pads or heater panels that have been assembled and/or
terminated in accordance with the manufacturer’s instructions for connection to voltage
supplies up to and including 450 V/750 V.
This Technical specification does not cover induction, impedance or skin effect heating.
Trace heating systems can be grouped into different types of installations. These are
characterized by different requirements for testing and are usually certified for a specific type
of installation or application. Typical applications for the different types of installation are as
follows:
a) Installations of trace heating on pipes, vessels and associated equipment. Applications
include:
– freeze protection and temperature maintenance;
– hot water lines;
– oil and chemical lines;
– sprinkler systems.
b) Outdoor exposed area installations of trace heating. Applications include:
– roof de-icing;
– gutter and downspout de-icing;
– catch basins and drains;
– rail heating.
c) Installation with embedded trace heating. Applications include:
– snow melting;
– floor warming;
– frost heave prevention;
– underground thermal energy storage systems;
– door frames.
d) Installations with trace heating inside conduit or piping. Applications include:
– snow melting – in conduit;
– floor warming – in conduit;
– frost heave prevention – in conduit;
– underground thermal energy storage systems – in conduit;
– internal trace heating of potable water lines;
– enclosed drains and culverts.
Best Sellers From Electrical Sector
YSMO GSO 2530:2023
GSO 2530:2016
Yemeni Technical Regulation
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
Recently Published from Electrical Sector
GSO IEC 60227-5:2026
IEC 60227-5:2024
Gulf Standard
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables (cords)
GSO ISO 20816-21:2026
ISO 20816-21:2025
Gulf Standard
Mechanical vibration — Measurement and evaluation of machine vibration — Part 21: Horizontal axis wind turbines
GSO CEN/TR 16999:2026
CEN/TR 16999:2019
Gulf Standard
Solar energy systems for roofs - Requirements for structural connections to solar panels
GSO IEC PAS 63629:2026
IEC PAS 63629:2025
Gulf Standard
PSR – Specific rules for luminaires