GSO IEC 60800:2013
IEC 60800:2009
Gulf Standard
Current Edition
·
Approved on
09 September 2013
Heating cables with a rated voltage of 300/500 V for comfort heating and prevention of ice formation
GSO IEC 60800:2013 Files
English
58 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
GSO IEC 60800:2013 Scope
This International Standard is applicable to, and specifies requirements for, resistive heating
cables for low temperature applications such as comfort heating and the prevention of ice
formation. These cables and cable sets may comprise either factory fabricated or field (worksite)
assembled units, and which are heating cables assembled in accordance with
manufacturer’s instructions.
Bare conductors and protected conductors to be supplied at voltages equal to, or less than,
50 V are excluded from the scope of this standard.
NOTE Terminations and gland fittings are outside the scope of this standard.
Typical applications include, but are not limited to:
• surface heating installed in or under surfaces;
• direct and storage heating;
• snow melting and frost protection of roofs, gutters, pipes, etc.
Heating cables for industrial and commercial applications are specified in the IEC 62395
series [1]1 as are mineral insulated heating cables.
Applications in which the operating sheath temperature exceeds 100 °C are outside the scope
of this standard.
The object of this standard is to ensure that electrical resistance heating cables operate
safely under their normal defined conditions of use. This is achieved by:
– employing heating cables of the appropriate construction that meet the test criteria
detailed in this standard;
– including, for cables with an electrical protective component, a metallic braid, concentric
wires or sheath, or other suitable electrically conductive material for protective purposes in
case of fault;
– ensuring that the cables operate at safe temperatures with respect to the materials used in
the construction of the cables and their installations according to national regulations.
Best Sellers From Electrical Sector
YSMO GSO 2530:2023
GSO 2530:2016
Yemeni Technical Regulation
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners


GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners

GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES

GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines

Recently Published from Electrical Sector
GSO 195:1994
Gulf Standard
METHODS OF TEST FOR
ADHESIVE INSULATING TAPES FOR
ELECTRICAL PURPOSES

GSO 31:1984
Gulf Standard
METHODS OF TEST FOR
PVC-INSULATED CABLES AND CORDS
WITH CIRCULAR COPPER CONDUCTORS

GSO 1842:2007
Gulf Standard
METHODS OF TESTING FOR PLUGS AND SOCKET OUTLETS FOR VOLTAGES FROM 127V AND UP TO 250V FOR HOUSEHOLD AND SIMILAR GENERAL USE

GSO 723:1997
Gulf Standard
Methods of test for telephone sets.