GSO EN 1998-3:2011 Scope
(1) The scope of Eurocode 8 is defined in EN 1998-1: 2004, 1.1.1 and the scope of
this Standard is defined in (2), (4) and (5). Additional parts of Eurocode 8 are indicated
in EN 1998-1: 2004, 1.1.3.
(2) The scope of EN 1998-3 is as follows:
− To provide criteria for the evaluation of the seismic performance of existing
individual building structures.
− To describe the approach in selecting necessary corrective measures
− To set forth criteria for the design of retrofitting measures (i.e. conception,
structural analysis including intervention measures, final dimensioning of structural
parts and their connections to existing structural elements).
NOTE For the purposes of this standard, retrofitting covers both the strengthening of
undamaged structures and the repair of earthquake damaged structures.
(3) When designing a structural intervention to provide adequate resistance against
seismic actions, structural verifications should also be made with respect to non-seismic
load combinations.
(4) Reflecting the basic requirements of EN 1998-1: 2004, this Standard covers the
seismic assessment and retrofitting of buildings made of the more commonly used
structural materials: concrete, steel, and masonry.
NOTE Informative Annexes A, B and C contain additional information related to the assessment
of reinforced concrete, steel and composite, and masonry buildings, respectively, and to their
upgrading when necessary.
(5) Although the provisions of this Standard are applicable to all categories of
buildings, the seismic assessment and retrofitting of monuments and historical
buildings often requires different types of provisions and approaches, depending on the
nature of the monuments.
(6) Since existing structures:
(i) reflect the state of knowledge at the time of their construction,
(ii) possibly contain hidden gross errors,
(iii) may have been submitted to previous earthquakes or other accidental actions with
unknown effects,
structural evaluation and possible structural intervention are typically subjected to a
different degree of uncertainty (level of knowledge) than the design of new structures.
Different sets of material and structural safety factors are therefore required, as well as
different analysis procedures, depending on the completeness and reliability of the
information available.
Best Sellers From Construction and Building Sector
GSO 1427:2008
Gulf Standard
Ceramic Sanitary Appliances - Western Water Closets
GSO 1431:2002
Gulf Technical Regulation
Sanitary appliances - pressurized flushing devices
GSO 2489:2015
Gulf Standard
Specifications of Recycled Aggregates from Construction
Waste to be used in construction Works
GSO 2084:2010
Gulf Standard
Design and application of speed control humps
Recently Published from Construction and Building Sector
GSO ISO 679:2026
ISO 679:2009
Gulf Standard
Cement — Test methods — Determination of strength
GSO ISO 50002-2:2026
ISO 50002-2:2025
Gulf Standard
Energy audits — Part 2: Guidance for conducting an energy audit using ISO 50002-1 in buildings
GSO ASTM C1170/C1170M:2026
ASTM C1170/C1170M:20
Gulf Standard
Standard Test Method for Determining Consistency and Density of Roller-Compacted Concrete Using a Vibrating Table
GSO EN 13888-1:2026
EN 13888-1:2022
Gulf Standard
Grouts for ceramic tiles - Part 1: Requirements, classification, designation, marking and labelling