GSO EN 1998-2:2011

EN 1998-2:2005
Gulf Standard   Current Edition · Approved on 12 April 2011

Eurocode 8 - Design of structures for earthquake resistance – Part 2 : Bridges

GSO EN 1998-2:2011 Files

English 147 Pages
Current Edition Reference Language

GSO EN 1998-2:2011 Scope

(1) The scope of Eurocode 8 is defined in EN 1998-1:2004, 1.1.1 and the scope of this Standard is defined in 1.1.1. Additional parts of Eurocode 8 are indicated in EN 1998-1:2004, 1.1.3. (2) Within the framework of the scope set forth in EN 1998-1:2004, this part of the Standard contains the particular Performance Requirements, Compliance Criteria and Application Rules applicable to the design of earthquake resistant bridges. (3) This Part primarily covers the seismic design of bridges in which the horizontal seismic actions are mainly resisted through bending of the piers or at the abutments; i.e. of bridges composed of vertical or nearly vertical pier systems supporting the traffic deck superstructure. It is also applicable to the seismic design of cable-stayed and arched bridges, although its provisions should not be considered as fully covering these cases. (4) Suspension bridges, timber and masonry bridges, moveable bridges and floating bridges are not included in the scope of this Part. (5) This Part contains only those provisions that, in addition to other relevant Eurocodes or relevant Parts of EN 1998, should be observed for the design of bridges in seismic regions. In cases of low seismicity, simplified design criteria may be established (see 2.3.7(1)). (6) The following topics are dealt with in the text of this Part: − Basic requirements and Compliance Criteria, − Seismic Action, − Analysis, − Strength Verification, − Detailing. This Part also includes a special section on seismic isolation with provisions covering the application of this method of seismic protection to bridges. (7) Annex G contains rules for the calculation of capacity design effects. (8) Annex J contains rules regarding the variation of design properties of seismic isolator units and how such variation may be taken into account in design.

Best Sellers From Construction and Building Sector

GSO 1431:2002
 
Gulf Technical Regulation
Sanitary appliances - pressurized flushing devices
GSO 1427:2008
 
Gulf Standard
Ceramic Sanitary Appliances - Western Water Closets
GSO 2084:2010
 
Gulf Standard
Design and application of speed control humps
GSO 440:2007
 
Gulf Standard
Calcium Silicate bricks

Recently Published from Construction and Building Sector

GSO ISO 52000-3:2024
ISO 52000-3:2023 
Gulf Standard
Energy performance of buildings — Overarching EPB assessment — Part 3: General principles for determination and reporting of primary energy factors (PEF) and CO2 emission coefficients
GSO EN 1634-3:2024
EN 1634-3:2004 
Gulf Standard
Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 3: Smoke control test for door and shutter assemblies
GSO ISO/TR 52016-2:2024
ISO/TR 52016-2:2017 
Gulf Standard
Energy performance of buildings — Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads — Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1
GSO ASTM C1354/C1354M:2024
ASTM C1354/C1354M:22 
Gulf Standard
Standard Test Method for Strength of Individual Stone Anchorages in Dimension Stone