GSO EN 13420:2026 Scope
This European Standard specifies the test methods for evaluating:
- the risks of decay of openable and fixed windows manufactured of different materials through increased moisture accumulation as a result of condensation or water vapour diffusion;
- the influence of deformation on basic performances of openable and fixed windows manufactured of different materials exposed to different climates between their external and internal faces.
Three test methods are to be differentiated. They take into account different cases of loadings.
- Test method 1: For designs with low resistance to water vapour diffusion (normally designs with water vapour equalization holes); the test procedure is to be used for cross-sections where the danger is given by the moisture accumulation as a result of the condensation of moisture between the planking and the timber (see Annex A (informative), Figure A.1).
- Test method 2.1 and 2.2: For designs with high resistance to water vapour diffusion (normally designs without water vapour equalization holes); the test procedure is to be used for cross-sections where the danger is given by the condensation of the moisture between the surface of the inner profile and the inner surface of the outer profile by having a different water vapour diffusion (see Annex A (informative), Figures A.2 and A.3).
- Test method 3: For designs being sensitive to deformation; the test procedure is to be used for cross-sections where they are sensitive to the function through deformation as a result of climatic loading.
This European Standard defines the test procedures which are to be used in dependence of the potential risk of the design.
This European Standard is relevant to initial type testing, i. e. to developments or changes in designs. It is not relevant to routine quality control or to proven designs.
NOTE Designs are included in Annex A (informative). Annex B (normative) is the survey of general design criteria where tests are not necessary.
Best Sellers From Construction and Building Sector
GSO 1427:2008
Gulf Standard
Ceramic Sanitary Appliances - Western Water Closets
GSO 1431:2002
Gulf Technical Regulation
Sanitary appliances - pressurized flushing devices
GSO 2489:2015
Gulf Standard
Specifications of Recycled Aggregates from Construction
Waste to be used in construction Works
GSO 2084:2010
Gulf Standard
Design and application of speed control humps
Recently Published from Construction and Building Sector
GSO ISO 16535:2026
ISO 16535:2019
Gulf Standard
Thermal insulating products for building applications — Determination of long-term water absorption by immersion
GSO ISO 679:2026
ISO 679:2009
Gulf Standard
Cement — Test methods — Determination of strength
GSO ISO 50002-2:2026
ISO 50002-2:2025
Gulf Standard
Energy audits — Part 2: Guidance for conducting an energy audit using ISO 50002-1 in buildings
GSO EN 13888-1:2026
EN 13888-1:2022
Gulf Standard
Grouts for ceramic tiles - Part 1: Requirements, classification, designation, marking and labelling