GSO IEC 60060-1:2026

IEC 60060-1:2025
Gulf Standard   Current Edition · Approved on 17 September 2026

High-voltage test techniques - Part 1: General terminology and test requirements

GSO IEC 60060-1:2026 Files

English 164 Pages
Current Edition Reference Language

GSO IEC 60060-1:2026 Scope

IEC 60060-1:2025 is applicable to:
- dielectric tests with direct voltage;
- dielectric tests with alternating voltage;
- dielectric tests with impulse voltage;
- dielectric tests with combinations of the above.
This document is applicable to tests on equipment having its highest voltage for equipment Um above 1,0 kV AC and 1,5 kV DC.
This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- The general layout and text have been updated and improved to make the standard easier to use, particularly the clauses for combined and composite test voltages.
- The positive tolerance of the front time of lightning impulse voltage has been extended for Um > 800 kV to 100 % (= 2,4 µs).
- For switching impulse voltage, a front time has been introduced, similar to lightning impulse voltage and with the new front time the standard switching impulse is defined as 170/2 500 µs.
- The requirements for precipitations have been adjusted depending on Um.
- A new Annex C, "Procedure for manual calculation from graphical waveforms" has been incorporated.
- No examples of software have been given in Annex D, "Guidance for implementing software for evaluation of lightning impulse voltage parameters".
- The annex relating to the "Background to the introduction of the test voltage factor for evaluation of impulses with overshoot" has been deleted.
- A new informative Annex F, "New definition of the front time of switching impulse voltage" has been incorporated.
NOTE 1 Alternative test procedures can be required to obtain reproducible and significant results. The choice of a suitable test procedure is considered by the relevant Technical Committee.
NOTE 2 For voltages Um above 800 kV it is possible that some specified procedures, tolerances and uncertainties will not be achievable.

Best Sellers From Electrical Sector

YSMO GSO 2530:2023
GSO 2530:2016 
Yemeni Technical Regulation
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines

Recently Published from Electrical Sector

GSO ISO 20816-21:2026
ISO 20816-21:2025 
Gulf Standard
Mechanical vibration — Measurement and evaluation of machine vibration — Part 21: Horizontal axis wind turbines
GSO CEN/TR 16999:2026
CEN/TR 16999:2019 
Gulf Standard
Solar energy systems for roofs - Requirements for structural connections to solar panels
GSO IEC 61362:2026
IEC 61362:2024 
Gulf Standard
Guidelines to specification of hydraulic turbine governing systems
GSO IEC TS 62271-313:2026
IEC TS 62271-313:2025 
Gulf Standard
High-voltage switchgear and controlgear - Part 313: Direct current circuit-breakers